Schluter DITRA-HEAT-E-HK Cable - 120V

Schluter Ditra Heat Cables are twisted pair heating cables designed to integrate with Ditra Heat Uncoupling Membrane in the Schluter Floor Warming System.
As low as $224.16

Brand: Schluter

Availability: Ships from Factory (More Info)

Shipping: Free to Continental US (More Info)

Only %1 left
SKU
DITRAHEAT 120V CABLE

The 120V Schluter Ditra Heat Cables (DITRA-HEAT-E-HK) are a twisted pair heating cable designed for integration with DITRA-HEAT Uncoupling Membrane in interior floor warming applications.

Schluter DITRA HEAT E HK 120V Floor Warming Cable Features:

  • Cables snap into the membrane; clips and fasteners are not required
  • No self-levelers required to encapsulate the cables; installation time significantly reduced
  • No return to thermostat required
  • Produces virtually zero electromagnetic fields
  • 120V and 240V options available in a variety of lengths

Important Schluter Ditra Heat Cable Ordering Information

  • Do not purchase a heating cable the same size as the area to be tiled; this will be too much heating cable!
  • Very important: Never CUT the heating cable. This would change the cable resistance and could lead to a fire.
  • Install the heating cable at a spacing of 3 studs (3-1/2" – 9 cm).
  • Minimum spacing from walls or fixtures (e.g., cabinets) is 3" (75 mm).
  • Minimum spacing from other heat sources (baseboard heaters, fireplaces, forced air heating ducts, etc.) is 8" (200 mm)
  • Minimum spacing from any plumbing drain is 6" (150 mm).
  • The heating cable section of the cable must be entirely installed under the floor covering. In order to prevent a fire hazard, do not install it anywhere else (e.g., in a wall).
  • Never install heating cable under vanities, bathtub platforms, kitchen cabinets and islands or any other fixtures. Excessive heat could build up in these confined spaces and may cause a fire.
  • It is helpful to plan the location of a buffer zone, as it is not possible to predict where the heating cable will end. The buffer zone is an area where heating is not essential, typically behind a toilet or adjacent to a door opening. This area allows for placement of excess heating cable.
  • Heating cable testing is required while the heating cable is on the spool and at two subsequent steps during installation to ensure cable quality and for warranty purposes. A megohmmeter is required for the insulation resistance testing of the heating cables.

Schluter DITRA-HEAT-E-HK 120V Floor Warming Cable Specifications:

Item No Heating Cable Length
(ft)
Area Covered per Cable Spacing Total Power
(W)
Avg. Power per Unit Area per Cable Spacing Current
(Amps)
Regular 3 Stud
(sq.ft)
Alternating 3-2 Stud
(sq.ft)
Regular 3 Stud
(Watts/sq.ft)
Alternating 3-2 Stud
(Watts/sq.ft)
DHEHK12011 35.3 10.7 8.9 135 12.6 15.2 1.1
DHEHK12016 52.9 16.0 13.3 203 12.7 15.2 1.7
DHEHK12021 70.5 21.3 17.8 270 12.7 15.2 2.3
DHEHK12027 88.2 26.7 22.2 338 12.7 15.2 2.8
DHEHK12032 105.8 32.0 26.7 405 12.7 15.2 3.4
DHEHK12038 124.1 37.5 31.3 475 12.7 15.2 4.0
DHEHK12043 141.1 42.7 35.6 540 12.7 15.2 4.5
DHEHK12051 169.8 51.4 42.8 650 12.7 15.2 5.4
DHEHK12064 212.9 64.4 53.7 815 12.7 15.2 6.8
DHEHK12073 240.2 72.7 60.6 920 12.7 15.2 7.7
DHEHK12083 275.5 83.3 69.4 1055 12.7 15.2 8.8
DHEHK12092 303.0 91.7 76.4 1160 12.7 15.2 9.7
DHEHK120102 336.9 101.9 84.9 1290 12.7 15.2 10.7
DHEHK120113 372.2 112.6 93.8 1425 12.7 15.2 11.9
DHEHK120134 444.0 134.3 111.9 1700 12.7 15.2 14.2

Download KERDI-DRAIN Installation Handbook
Download Ditra Heat Calculation sheet
Download Ditra Heat Data Sheet
Download Schluter Ditra Heat Brochure

More Information
SKU DITRAHEAT 120V CABLE
Non-Returnable No
Manufacturer Schluter
Warranty Limited 10 Year Warranty
Voltage 120
Weight (lbs.) 3.02 - 13.45
Dimensions (L x W x H) 13" x 12" x 4"
Write Your Own Review
You're reviewing: Schluter DITRA-HEAT-E-HK Cable - 120V
Customer Questions
Is a sensor included with the wire?
No, the sensor wire is included with the Thermostats.  
Did you find what you were looking for?